Graphical User Interface (GUI) Quickstart

This first-use guide takes you from a prepared soluble protein to standard SILCS simulations, generated FragMaps, and a basic visualization check. Other suites and advanced analyses are covered in their module chapters.

Before starting, you need the SilcsBio GUI, access to a licensed server installation with GROMACS and the required dependencies, compute resources, and sufficient project storage. See SilcsBio Installation for installation requirements and SILCS Simulations for protein preparation. Use the same prepared protein throughout the workflow.

SilcsBio GUI Suite Selection

The SilcsBio GUI provides convenient access to cutting-edge SILCS and CGenFF technologies for computer-aided drug discovery. Currently, four suites are available through the SilcsBio GUI:

  1. Small Molecule Suite

  2. Biologics Suite

  3. SSFEP Suite

  4. CGenFF Suite

Upon opening the SilcsBio GUI, the user will directly enter the Small Molecule Suite. To access different suites, select the desired suite from the menu bar.

For this first workflow, stay in the Small Molecule Suite. Links to the other suites appear under What next? at the end of this guide.

Remote Server Setup

The SilcsBio GUI is designed to work with the server installation of the SilcsBio software. Launch the GUI and select Settings and remote server configuration.

Within the “Settings and remote server configuration” page, select Server and enter the remote server information, such as Server Address (IP address), Username, and an SSH key to the server. If you do not have an SSH key to the server, leave it blank. The GUI will ask you the password to the remote server instead. Select the “Make Default Server” checkbox if you would like to set this server as your default server. This server will be selected as a default in other parts of the GUI.

You will also need to enter SILCSBIODIR and GMXDIR file path values. These should match the values on your server. You may use the “Extra setup” field to pass additional commands to the server, such as exporting environment variables or loading modulefiles.

Note

The SilcsBio GUI will enter a reset environment on the remote server. Thus, you need to manually add all necessary packages (e.g., python) in the PATH.

You may use the “Project Directory” field to define the directory on your server where server job input files will be created and server job outputs stored. Typical SILCS simulations produce output files in excess of 100 GB, so please select a project directory file folder with appropriate storage capacity. The “SILCS NUMSYS” field determines how many SILCS jobs are launched for creating FragMaps. Set this to an even integer; we recommend “10” to maximize convergence or “8” to minimize resource use.

Once all information is entered, click the “Save” button. The GUI will save your entries and confirm that you have a working connection to the server.

Please contact support@silcsbio.com if you need additional assistance.

File and Directory Selection

To run the SilcsBio software, you will need to provide protein and/or ligand input files. The SilcsBio GUI has a standardized user interface that allows you to choose these input files from either the computer on which you are running the GUI or from a remote server you have previously configured. Steps to do this, illustrated in the below figures, are as follows:

  1. Choose the server on which is the physical location of the input file is located. If you would like to load a file located on the computer on which you are running the GUI, click Local; otherwise, click Remote and select the remote server name of a server you have previously configured through the Remote Server Setup process.

  2. If the file is located on the local computer, click Open file browser. This will open your local computer’s native file browser. Select your file following the conventions of your local computer.

    Otherwise, if the file is located on a remote server, type in the folder where the file is located using the “Go to the folder” field and then click the associated Go button. This will update the “Current location” to this folder. Click on the last portion of the “Current location” path (e.g. “silcsbio” in “/state/partition1/home/asukaorr/silsbio” in the below example) to update the directory listing located under that path. If you click on any other portion of the “Current location” path, you will be taken to that folder. Double clicking on a folder in the directory listing will move you into that folder. In the directory listing, click on a file to highlight it and click the Select This File button at the bottom to finish your file selection.

Follow a similar process to select a directory for those tasks requiring directory selection.

Tip

For those tasks needing FragMaps as inputs, “FragMap Location” needs to be a directory. The SilcsBio GUI assumes a directory path of the form <basename>/maps/. Select <basename> for your “FragMap Location”. The GUI will automatically look for the maps/ subdirectory and load FragMaps from that subdirectory. It will also automatically load the protein pdb file if one is located in the <basename> directory. It may take a few seconds for the GUI to download your input FragMaps if they are not on localhost.

Your First SILCS Project

Complete the server configuration above and prepare a protein PDB containing the chains needed for your system. Resolve missing atoms and nonstandard residues before starting; consult SILCS Simulations for detailed preparation and workflows requiring ligands, membranes, RNA, or other variants.

SILCS Simulations Using the GUI

To begin a new SILCS project, follow these steps:

  1. Begin a new SILCS project:

    Select New SILCS project from the Home page.

  2. Select the macromolecule target type:

    Click on the desired macromolecule type (Globular Protein, Membrane Protein, or RNA). For the purposes of this GUI quickstart, the following instructions are focused on running standard SILCS simulations for Globular Protein target types. For additional details on SILCS for Membrane Protein, or RNA target type, please see SILCS Simulations.

  3. Enter a project name, select the remote server, and upload input files:

    Enter a project name and select the remote server where the SILCS jobs will run. Input and output files from the SILCS jobs will be stored on this server based on your choice of “Project Directory” during the Remote Server Setup process.

    Next, select a protein PDB file. As described in File and Directory Selection, choose a file from your local computer (“localhost”) or from any server you had configured through the Remote Server Setup process. We recommend cleaning your input PDB file before use, incuding keeping only those protein chains that are necessary for the simulation, removing all unnecessary ligands, renaming non-standard residues, filling in missing atomic positions, and, if desired, modeling in missing loops.

    If the GUI detects missing non-hydrogen atoms, non-standard residue names, or non-contiguous residue numbering, it will inform the user and provide a button labeled “Fix?”. If this button is clicked, a new PDB file with these problems fixed and with the suffix _fixed added to the PDB file base name will be created and used. The SilcsBio GUI will not model residues that are completely missing from the PDB or loops.

  4. Set up SILCS simulations:

    Press the “Setup” button at the bottom of the page. The GUI will contact the remote server and perform the SILCS GCMC/MD setup process. During setup, the program automatically performs several steps: building the topology of the simulation system, creating metal-protein bonds if metal ions are found, rotating side chain orientations to enhance sampling, and putting probe molecules around the protein. To complete the entire process may take up to 10 minutes depending on the system size. A green “Setup Successful” button will appear once the process has successfully completed. Press this button to go to the next step.

  5. Launch SILCS simulations:

    Your SILCS GCMC/MD simulation can now be started by clicking the “Run SILCS Simulation” button. Before running, you may wish to double check that you have chosen the desired file folder on the remote server and that it has 100+ GB of storage space.

    Compute jobs will be submitted to the queueing system on the server.

    The status of each job is shown next to its progress bar: “Q” for queued, an orange clock and “Running” for running, “NA” for not submitted, and “F” for failed. When a job successfully completes, its progress bar will turn green.

    Once your jobs are in progress, in either the queued or running state, you may safely quit the SilcsBio GUI or go back to the Home page to do other tasks.

    If a job encounters an error or you cancel it before it finishes, its progress bar will turn red. “Restart” will appear next to the progress bar. Pressing “Restart” will resubmit the job to the queue and continue from the last cycle of the calculation so that previous progress on that job is not lost.

  6. Generate FragMaps:

    Once your SILCS compute jobs are finished, the GUI can be used to create FragMaps and visualize them. Green progress bars indicate successful job completion. Once all progress bars are green, the “Prepare FragMap” button will appear.

    Press this button, and on the next screen, confirm your “Reference PDB File.” FragMaps will be created in the coordinate reference frame of this file. Generally, this reference PDB file is the same as the protein PDB file. A different file with the protein in a different orientation can be selected if you want to generate FragMaps relative to that orientation. Click “Generate FragMap” to generate FragMaps and download them to the local computer for visualization.

    Tip

    If you plan to compare FragMaps from two different protein structures, you will want to generate them with the same orientation. In that case, pre-align your input structures with each other and use these aligned coordinates as your Reference PDB Files.

Processing the GCMC-MD trajectories will take 10-20 minutes, with the GUI providing updates on progress from the server during the process.

Once completed, the GUI will automatically copy the files from the server to the local computer and load them for visualization. Please see Visualizing SILCS FragMaps for details on how to use the SilcsBio GUI, as well as external software (MOE, PyMol, VMD), to visualize SILCS FragMaps.

  1. Continue SILCS projects:

    To see a full listing of all of your projects, select Continue SILCS project from the Home page. This will show the complete list of all SILCS projects you have set up on the local machine where you are currently running the SilcsBio GUI, as well as the status of each project.

    To resume work on a project or check the status of associated compute jobs you previously started, simply click the project name in the list.

Data from SILCS simulations are used to pre-compute SILCS FragMaps, which are the basis for a host of functionality. The FragMaps can be used for detecting hotspots and fragment-based drug design (SILCS-Hotspots), creating pharmacophore models (SILCS-Pharm), docking ligands and refining existing docked poses (SILCS-MC: Docking and Pose Refinement), and optimizing a parent ligand (SILCS-MC: Ligand Optimization).

For additional details on SILCS, please see SILCS Simulations.

SILCS FragMap Visualization Quickstart

After FragMap generation completes, the GUI can download and open the matching protein and maps. To open them later, select Visualize SILCS FragMaps and Ligand Analysis from the Home page, then choose the generated silcs_fragmaps_<target> bundle, not its maps/ subdirectory. <target> is the prepared protein filename stem.

Show or hide one FragMap using its representation toggle and adjust its GFE isosurface threshold. Confirm that the expected protein is displayed and that the maps overlay it in the same coordinate frame.

You have completed the first workflow when all requested simulation and map jobs have finished successfully, the FragMap bundle is present, and its matching protein and maps open together. A visual check does not establish simulation convergence or validate a binding prediction.

Keep the bundle’s protein, maps/, viewing scripts, and plugins together. Retain source trajectories if you may need new maps or frame selections; cleanup is optional, not part of this first workflow.

For saved viewing sessions, atom selections, ligand loading, and advanced controls, see GUI Display Controls and Ligand Analysis and Visualizing SILCS FragMaps.

What next?